“Needs a live {dataset} licence on your Databento plan” in Senzoukria

Senzoukria measures what your Databento key can open before letting a module use it. A module switch stays disabled with “Needs a live {dataset} licence on your Databento plan” when the dataset it requires is not live on your key.

Senzoukria · Troubleshooting · Updated September 2026


At a glance

Message
“Needs a live {dataset} licence on your Databento plan”
Datasets checked
GLBX.MDP3 (CME), OPRA.PILLAR (OPRA), ARCX.PILLAR (ARCX, SPY)
Modules
Footprint + heatmap needs CME · GEX needs OPRA and ARCX · Options flow needs OPRA
Where
Account → Broker Connections → API Keys → Databento

What you see

In the Databento section, the line “Licence (measured on your key)” shows each dataset as “live” or “data until {time} UTC”. Under “Use this key for”, a switch is disabled and explains “Needs a live CME licence on your Databento plan”, or OPRA, or ARCX (SPY). Hovering a dataset shows the error or end date behind it.

Why it happens

A Databento key only opens the datasets of its subscription. On 10 September 2026, a user’s key had CME live but neither OPRA nor ARCX. A switch that enabled a module without a licence would give an empty screen that looks like a calm market, so it stays disabled and the reason is written. The check reads the accessible date range of each dataset, which Databento serves free of charge; a range that reaches the present counts as live.

The GEX module needs two datasets: the options chain from OPRA and the SPY price from ARCX.

How to fix it

  • Add the missing dataset to your Databento plan, then click “Re-check”.
  • Use another source for that module meanwhile: Tradier, Alpaca or Market Data for GEX; Tradier or Alpaca for Option Flow; Rithmic or a bridge for the footprint.
  • Remember that GEX and Option Flow on Databento read OPRA with about 15 minutes of delay: the module labels say “GEX (OPRA, ≈15 min behind)” and “Options flow (OPRA, ≈15 min behind)”.

What it is not

  • Not a wrong key: an invalid key fails the check with an error instead of showing dates.
  • Not an app restriction: the licence is measured on your key, not assumed.

When to contact support

When none of this helps, write to support through Menu → Report a problem or on the Senzoukria Discord. Copy the Licence line and the tooltip error of the dataset that fails.

In the same section

This page in other languages

Frequently asked questions

Does the app choose Databento automatically for GEX?
No. Databento is billed by usage on your account, so it is never picked as an automatic fallback; you select it in the GEX header.
What does “data until {time} UTC” mean?
Your key reaches that dataset only up to that time, so it is not live. Historical use may still work, but the live module stays disabled.

Keep reading